Ph: +61 2 49543900 Fax: +61 2 49543999  sales@pcwi.com.au

13 Alhambra Ave Cardiff N.S.W. 2305 Australia

Coating Thickness :

Calibration Standard:

Positector 6000 S Coating Thickness Paint Gauge

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

**NEW**
Positector 6000 S Separate Probe Model.
This Gauge accommodate various interchangeable probes. Extended probe cable is available.
Ferrous Gauge F, Measures non-magnetic coatings on steel.
Non-Ferrous Gauge NF, Measures non-conductive coatings on aluminium, brass etc.
Ferrous and Non-Ferrous gauge FN, Measures both, non-magnetic coating on steel AND non-conductive coatings on aluminium, brass etc, AUTOMATICALLY recognizes the substrate and takes a measurement
Application Types A, B, C. Commonly known as paint gauges. Complies with the requirements of Australian Standard AS3894.3-2002.
Range
  Ferrous- Steel, Cast iron, Ferritic Stainless steel, Etc
    0 to 1150µm
    0 to 1500µm
    0 to 6mm
    0 to 13mm
  Non-ferrous- Aluminium, Stainless steel, Copper, Brass,
    0 to 50µm
    0 to 625µm
    0 to 1500µm
    0 to 6mm
    0 to 13mm
  FN- measures on both substrates
Ferrous- Steel, Cast iron, Ferritic Stainless steel, Etc
Non-ferrous, Aluminium, Stainless steel, Copper, Brass,
    0 to 1500µm
    0 to 6mm

Click here Download the product Data Sheet

Click Here to Request Pricing